Actronic-Solutions

Beschreibung für einen Lastungszyklus mit unterschiedlichen Einschaltdauern im intermitterenden Betrieb bis zu 100% Einschaltdauer

CALCULATION TOOL FOR THE LOAD CYCLE OF SOLENOIDS AND ROTARY SOLENOIDS (RELATIVE DUTY CYCLE VS. OPERATING VOLTAGE)

calculation of the allowed voltage for a desired duty cycle
based on a known duty cycle
Formula: U2 = U1*(√(α1/α2))

duty cycle with known values α1 [%]
voltage of duty cycle
with known values
U1 [V]
duty cycle to be calculated α2 [%]
allowed voltage* at this
duty cycle [V]
U2 [V]
   
* mind the maximum on-time per cycle!



calculation of the allowed duty cycle for a desired voltage
based on a known duty cycle
Formula: α2 = α1*(U1/U2)²

duty cycle with known values α1 [%]
voltage at duty cycle
with known values
U1 [V]
voltage to be calculated with U2 [V]
allowed duty cycle* at this
voltage
α2 [%]
   
* mind the maximum on-time per cycle!
 
number of decimal digits should be shown on the result

*** An important note:
We have tested our tools carefully. Nevertheless, we cannot exclude the possibility that errors have crept in with the large number of formulas and links. Also the accuracy of the calculations will depend on the proper use of tables and the accuaracy of the input by the user.  Therefore: All calculations are made at your own risk. We assume no liability for the correctness of the calculated results displayed. In case there are any questions, please contact us via the contact form!